Description / Ölflex classic 110 4x0,75 r100

ÖLFLEX CLASSIC 110
VDE-registered oil-resistant PVC control cable for a wide range of applications
ÖLFLEX®® CLASSIC 110 - PVC control cable, VDE registered, oil resistant and flexible for various applications, 300/500V, alsofor YSLY or YY
CPR: see www.lappkabel.dk
VDE certificate of conformity with factory surveillance.
Very broad range, items with up to 100 conductors
For fixed installation as well as occasional flexing at free, non-continuously recurring movement without tensile load
Dry or damp rooms that are subject to medium mechanical loads
Suitable for torsional applications which are typical for the loop in wind turbine generators (WTG)
In power chains for a travelling distance up to 5 m and 0,2 ... 1 million bending cycles, for following dimensions: 0,5 to 2.5mm² and 2 to 7 conductors.
Flame-retardant according IEC 60332-1-2
Good chemical resistance.
Oil-resistant according to DIN EN 50290-2-22 (TM54)
VDE reg. no. 7030 for the following sizes:
up to 2.5 mm²: 2 - 65 cores
from 4 mm²: 2 - 7 cores
from 25 mm²: 2 - 5 cores
Fine-wire strand made of bare copper wires
PVC insulation LAPP P8/1
Cores twisted in layers
PVC outer sheath, grey (similar RAL 7001)




Core identification code: Black with white numbers acc. to VDE 0293-1
Conductor stranding: Fine wire according to DIN EN 60228 (VDE 0295), class 5 / IEC60228 class 5
Torsion movement in WTG: TW-0 & TW-1.
Minimum bending radius: Occasional flexing: 10 x outer diameter
In power chains: 15 x outer diameter. Fixed: 4 x outer diameter
Nominal voltage: U0/U: 300/500 V
Test voltage: 4000 V
Protective conductor: G = with GN-YE protective conductor. X = without GN-YE
Temperature range: Occasional flexing: -15°C to +70°C
In power chains: -5°C to +70°C
Fixed installation: -40°C to +80°C

Link to manufacturer:
Lapp
Lapp

More Information

Approved outside temperature, fixed cable-40 - 80 °C
Approved outside temperature, movable cable-15 - 70 °C
BrandLAPP
Cable clipNo
Cable geometry?Rund
Cold resistant according to EN 60811-504 + 505 + 506No
Color outer sheathGrå
Conductor insulationPVC
Conductor markingNumre
Conductor surfaceBlank
Couple buildingNo
Description1119804/100
Dual use (US)EAR99
EAN number4044774556956
EL number5435011779
Euro class acidity according to EN 13501-6None
Euro-class flaming droplets / particles according to EN 13501-6None
Fire retardantIht. IEC/EN 60332-1-2
Flame retardant per IEC 60332-1-2Yes
Flame retardant per IEC 60332-3-21 (Cat A F/R)No
Flame retardant per IEC 60332-3-22 (Cat A)No
Flame retardant per IEC 60332-3-23 (Cat B)No
Flame retardant per IEC 60332-3-24 (Cat C)No
Flame retardant per IEC 60332-3-25 (Cat D)No
Food contact materialNo
Halogen-free (according to EN 60754-1 / 2)No
Halogen-free (according to IEC 60754-2)No
Halogen-free per IEC 60754-1No
Halogen-free per IEC 60754-3No
Individual displayNone
Leader classKlasse 5 = mangetrådet
Leadership materialKobber
Low smoke generation according to EN 61034-2No
Low smoke generation according to IEC 61034-2No
Min. Permissible bending radius, forced guide93 mm
Min. permissible bending radius, freely movable93 mm
Min. Permissible bending radius, permanent24.8 mm
Nominal conductor cross-section0.75 mm²
Number of managers4
Oil resistant (IEC 60811 to 404)Yes
Outer diameter6.2 mm
Outer jacket materialPVC
Pack size100
Protection managerNo
Rated voltage U500 V
Rated voltage U0300 V
REACH – contains substances from the Candidate List?No
Reaction class fire according to EN 13501-6Eca
RoHS compliantYes
ScreenNo
Screen over foilNone
SeriesÖlflex Classic 110
Smoke development class according to EN 13501-6None
Stock itemNo
Unitm
UNSPSC26121641
With protective conductorNo
loader